Back to blog

British Columbia’s combustible dust rules take effect January 4, 2027

WorkSafeBC’s combustible dust division, OHS Regulation ss. 6.133 to 6.159, takes effect January 4, 2027. What employers that handle dust must assess and prepare.

November 18, 2026

From January 4, 2027, an employer in WorkSafeBC jurisdiction that generates or handles dust must find out whether the dust can ignite or deflagrate, and manage the risk if it can. The duties sit in a new combustible dust division of Part 6 of the Occupational Health and Safety Regulation, sections 6.133 to 6.159. WorkSafeBC’s Board of Directors approved the amendments at its November 14, 2025 meeting, and the BC Laws consolidation lists them as B.C. Reg. 229/2025, Appendix B, among amendments not yet in force.

Today the regulation deals with dust build-up in a single sentence, section 5.81, which requires accumulated combustible dust to be removed safely before it could cause a fire or explosion. That section is repealed on January 4. APT’s British Columbia combustible dust record lists the new sections, the consequential amendments and the limits on where the division applies.

Which dust and workplaces are covered

The division applies to dust that is an input, product, byproduct or waste of a work process (s. 6.134(1)). It does not apply to a workplace where there is no reasonably foreseeable risk of injury or death to a worker from dust combustion, or to dust in a sealed commercial package (s. 6.134(2)).

Dust is presumed to be both ignitable and deflagrable. An employer can set that presumption aside only with a written determination, made in consultation with a qualified person and based on a recognized screening test or published test data (ss. 6.137 to 6.139).

What employers must prepare

Section 6.135 requires an employer that generates or handles dust to minimize its combustion risks. Where the dust is combustible, the employer prepares a written combustion risk assessment with a qualified person (s. 6.140). The assessment covers dust on surfaces, dispersion in air, confinement, ignition sources and oxidants, and it is updated after a significant change to buildings, equipment or work processes.

If the assessment identifies a combustion hazard, the employer also needs:

  • a written combustible dust management program with inspection schedules and response procedures, reviewed by a qualified person at least once a year (ss. 6.141 and 6.142)
  • instruction and training for each worker who could be exposed to the combustion risk (s. 6.143)
  • the risk controls in sections 6.147 to 6.159, which cover ignition sources, suspended dust, bulk storage, dust capture and removal, metal dust, fire and deflagration

The joint committee or worker representative must be consulted on the assessment, the program and the training (s. 6.136). Determinations, assessments and programs are dust records. They are kept for as long as the dust is generated or handled and must be available to workers (ss. 6.144 and 6.145).

The same amendment rewrites section 4.42(1), so compressed air or steam may not be used to blow dust where it could cause a fire, explosion or other event likely to result in injury or a health hazard. It also removes the dust collector siting rule in section 5.71(3). Fire departments and industrial fire brigades will need written procedures for fires and other emergencies involving combustible dusts (s. 31.5(2)).

Limits on the new division

The division sets program and housekeeping duties. It contains no airborne exposure limit, so inhalation exposure to the same dust is still assessed under the exposure-limit rules in Part 5.

Mines regulated under the Mines Act follow the Health, Safety and Reclamation Code for Mines. APT does not treat this WorkSafeBC division as applying to those sites automatically.

APT’s practical interpretation is to start with an inventory of each dust stream on site, then decide for each one whether to accept the presumption or obtain screening results. The risk assessment, any management program and worker training all need a qualified person or committee consultation, so they take time to complete before January 4. Cleaning procedures that use compressed air are worth checking against the revised section 4.42 at the same time.

Other dust and exposure developments are listed in APT’s industrial hygiene regulatory tracker.

Get regulatory news updates

Receive updates on industrial hygiene and workplace exposure regulations in the US, Canada, and Australia.

Take a tour of APT's dust management platform

Vulcan Materials Company is the nation’s largest producer of construction aggregates.

Project partner

Brent Leclerc | Environmental Manager

Problems solved

Unjustified community dust complaints & lawsuits

Difficulty complying with opacity regulations and risk of NOVs

Solution

Real-time dust monitoring

Dust maps proving no community impact, preventing fines & lawsuits

Real-time opacity monitoring, high degree of compliance

Case study overview

Share this article

Better decisions start with real-time insight

APT helps industrial teams move faster, act smarter, and stay compliant—because when you can see the problem clearly, you can solve it confidently.